Fuel Flow option for EDM-730, With 231 transducer, Harness included
$436.00
Fuel Flow option for EDM-730, With 231 transducer, Harness included
JP Instruments Fuel Flow Transducer Model 231
Not compatible with 9-cylinder engines
The Fuel Flow Transducer measures flows of hydrocarbon fuels such as gasoline, kerosene, and #2 diesel fuel and other light transmitting, non-corrosive liquids of similar viscosity. Typical fuel flow applications include aircraft fuel monitoring systems; gasoline, diesel, and gas turbine engine test stands; and industrial furnaces.
The transducers give repeatable signals on gasoline across a 100 to 1 flow range down to 0.3 GPH. The higher viscosity of diesel fuel reduces signal repeatability at flow rates below 2 GPH. Pressure drops are very low compared to other turbine flow transducers. The transducer bearing system is rated for continuous operation at the upper end of the flow range.
The transducers produce a current pulse signal from an opto-electronic pickup with a preamplifier.
Electrical Specifications:
12 to 15 VDC between RED (+) wire and BLACK (-) wire. 30 to 50 mA at 12 VDC.
Signal Specifications:
Open collector transistor output on WHITE wire. Sensor will pull-down to 1.0 volt with 10-15k ohm pull-up resistor installed.
Range (201) 0.6 to 60 GPH, (231) 3 to 90 GPH, (H) 3 to 120 GPH
K-factor (201) ~ 29.00, (231) ~19.50, (H) ~48.00
Linearity 1%
Pressure drop (201) 1.2 psi at 30 GPH, 4.8 psi at 60 GPH
Pressure drop (231) 0.31 psi at 30 GPH, 2.8 psi at 60 GPH
Pressure drop (H) 0.23 psi at 30 GPH, 0.8 psi at 60 GPH
Working pressure (201, 231) 200 psi, (H) 1500 psi
Maximum burst pressure 2000 psi
Temperature range, operating -55°C to 70°C
Temperature range, non-operating (201, 231) -65°C to 125°C, (H) -65°C to 100°C
Fuel ports (201, 231) 1/4 Female NPT (H) AN816-8-8
Install Overview:
Make sure the transducer is Horizontal with the three wires up. Failure to do this will result in premature failure. Please refer to Report #503 that came with your EDM with Fuel Flow.
Mount in a horizontal position with the wires up, as this ensures that the rotor is in proper orientation to the flow of fuel just as it was calibrated.
Be sure there is no bend in the line closer than 6 inches before or after the transducer. Do not use aluminum fittings when installing the fuel flow transducer.
For carbureted engines, before the carburetor. If the transducer is higher than the carburetor, put an anti-siphon loop in the line that peaks higher than the transducer (see installation manual, but the diagram shows the transducer on its side, rather than the correct position which is with the wires coming off the top).
For injected engines, between the engine fuel pump and the servo regulator. For injected engines with vapor return lines (rare), between the servo regulator and the flow divider (spider).
Mounting the transducer between the electric boost pump and the mechanical pump is not recommended.
Do not hard mount the transducer to the engine. Vibration may damage the internal parts of the transducer or cause erratic readings.
Tighten fittings not more than 15 ft lb = 180 in lbs., or two full turns past hand tight.
** Do not use Teflon tape or thread sealant compound of any kind – this will void transducer warranty.**
Related products
CGR-30P 4-Cylinder Primary Twin Engine Monitors, Premium (2 Monitors) w/RPM, EGT/CHT & 10 Functions
- Models: CGR-30P
- FAA Certifications: STC’d, PMA’d and TSO’d
- Weight: 1.1 Lbs
- Environmental: Designed and Tested to TSO (DO-160G)
- Software: Designed and Documented to TSO (DO-178B, Level C)
- Minimum Performance Standards: TSO-C43c, TSO-C44c, TSO-C45b, TSO-C47a, TSO-C48a, TSO-49b and TSO-C55a
- Power Requirements: 7.5 to 30 Volts, 0.1 amps @ 24V (Typ), 0.2 amps @ 12 Volts (Typ)
- USB Port: For USB Memory Stick use only
- Display: Active Matrix TFT, 262,144 colors, Sunlight readable
- Backlight: External control line, programmable levels
- Display of Primary Gauges with Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, One on the Secondary Screen
- Display of Primary and Non-Primary Gauges without Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, Six on the Secondary Screen
Electronics International MVP-50 Glass Panel Engine Monitor for 6 cylinder, TSO
MVP-50 Display
Weight:1.9 Lbs. Environmental: TSO'd to DO-160 Software: TSOd to DO-178B Power Requirements: 7.5 to 30 Volts, .3 Amps @24V (Typical), .6 Amps @ 12V (Typical). USB Port: For USB Memory Sticks Only (not intended to provide power to other electronic devices) Display: Active TFT Matrix, 262,144 colors. Sunlight readable. Backlight: External Control Line and Internal Electric EyesEDC-33P-4/6
Weight: 1 Lbs. Environmental: Meets TSO (DO-160) Software: Designed and documented to TSO (DO-178B) Power Requirements: 7.5 Volts to 30 Volts, 0.1 amps (Typical).Inputs
Volts: Measured on the power lead of the EDC. Amps: +/- 2.5V differential input, +/- 90V common mode operating range Fuel Flow: 2.5V trigger, 5.11K Ohm pull-up to +5V, 0 to 8.3KHz. RPM: 2 ea. inputs, may be configured for digital or mag input. Selectable jumper for 4 or 6 Cylinder operation. Over voltage protection for RPM: 3V trigger, impendence = 2.06K with 1V pickup. Pressure: 6 ea. inputs, 0 to 2.5V differential input. Impendence >20M Ohms, common mode = 0 to 4 Volts. Temperature: 17 ea. inputs, 0 to 2.5V differential input. Impendence = 12.1K Ohms, common mode = 0 to 4V. Resistive Fuel Level: 4 ea. inputs, 0 to 18V single ended input, impendence = 14.4K Ohms Capacitive Fuel Level: 4 ea. inputs, 0 to 6 KHz. 2.1V trigger, impendence = 33.2K OhmsElectronics International MVP-50 Glass Panel Twin Engine Monitors for 4 cylinder, TSO
MVP-50 Display
Weight:1.9 Lbs. Environmental: TSO'd to DO-160 Software: TSOd to DO-178B Power Requirements: 7.5 to 30 Volts, .3 Amps @24V (Typical), .6 Amps @ 12V (Typical). USB Port: For USB Memory Sticks Only (not intended to provide power to other electronic devices) Display: Active TFT Matrix, 262,144 colors. Sunlight readable. Backlight: External Control Line and Internal Electric EyesEDC-33P-4/6
Weight: 1 Lbs. Environmental: Meets TSO (DO-160) Software: Designed and documented to TSO (DO-178B) Power Requirements: 7.5 Volts to 30 Volts, 0.1 amps (Typical).Inputs
Volts: Measured on the power lead of the EDC. Amps: +/- 2.5V differential input, +/- 90V common mode operating range Fuel Flow: 2.5V trigger, 5.11K Ohm pull-up to +5V, 0 to 8.3KHz. RPM: 2 ea. inputs, may be configured for digital or mag input. Selectable jumper for 4 or 6 Cylinder operation. Over voltage protection for RPM: 3V trigger, impendence = 2.06K with 1V pickup. Pressure: 6 ea. inputs, 0 to 2.5V differential input. Impendence >20M Ohms, common mode = 0 to 4 Volts. Temperature: 17 ea. inputs, 0 to 2.5V differential input. Impendence = 12.1K Ohms, common mode = 0 to 4V. Resistive Fuel Level: 4 ea. inputs, 0 to 18V single ended input, impendence = 14.4K Ohms Capacitive Fuel Level: 4 ea. inputs, 0 to 6 KHz. 2.1V trigger, impendence = 33.2K OhmsEngine Data Monitor 930 System, 4 Cylinder Complete Primary Package, L/R/Aux 4 Tank, Experimental
- Dimensions: 5.97 x 5.11, 2.99 deep
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGTs
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-930 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 930 System, 6 Cylinder Complete Primary Package, L/R 2 Tank, Experimental
- Dimensions: 5.97 x 5.11, 2.99 deep
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGTs
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-930 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 930 System, 9 Cylinder Complete Primary Package, L/R/Aux 4 Tank, TSO/STC, Includes a High Flow Fuel Transducer to 125 GPH
- Dimensions: 5.97 x 5.11, 2.99 deep
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGTs
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-930 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 960 System, 4 Cylinder Complete Primary Package, L/R 2 Tank, TSO/STC
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGT’s
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-960 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty