Engine Data Monitor 730 System, 4 Cylinder
$1,347.00
EDM-730 Specifications |
|
|
|
Standard Functions of the EDM-730 |
Optional functions of the EDM-730 |
|
|
Engine Data Monitor 730 System, 4 Cylinder, JP Instruments
EDM-700/800/740 (EXP), EDM-730/830, EDM 760/790 Twin Order Form
Configuration & Option questionnaire must be completed prior to shipping
EDM-730/830 Pilots Guide
Package Includes: Display w/Harness, EGT & CHT Probes w/Harness, Pilots Guide, USB Stick
ALL EDM SYSTEMS are TSO’d and FEATURE:
- LeanFind ™ Performs ROP and LOP, automatically finds the first and last cylinder to peak
- Shock cooling checked on all cylinders with an alarm on the cylinder with the highest cooling rate
- Voltage, For alternator failure, monitored for over and under voltage with alarms
- Pilot Programmable Hi & Lo alarm limits. ALL programming from front panel
- All EDM’s TSO’d for quality with a 3 yr. Warranty on the Electronics
- Quick response probes, fastest accurate readings, pre-made harness and hardware
- Data Memory, reading once every 2 to 255 seconds
- EZPlot-1 program for plotting and downloading data
- USB download port built in with memory stick (730/830/790/900 Only)
- Full color TFT screen 4 inches Diagonal (730/830/790/900 Only)
EDM-730 Specifications |
|
|
|
Standard Features of the EDM-730 |
Optional functions of the EDM-730 |
|
|
The Engine Data Management 730 system is the most advanced and accurate piston engine-monitoring instrument on the market. TSO’d for quality, the EDM 730 is not just another black box along for the ride. It is a Flight Engineer … a Maintenance Manager … a Backup Instrument. For the price there is nothing that gets close to it. You can also think of the EDM 730 as your personal flight engineer. It’s always there, working in the background, constantly watching over your engine while you concentrate on flying the aircraft. You can make an entire flight without ever pushing a button, if you so choose. Yet your EDM will be monitoring your engine parameters three times a second and will warn you instantly if any parameter exceeds the programmed limit. With the EDM 730, it is now possible to have substantially more diagnostic information available to you in a timely and usable manner.
- Improved engine efficiency
- Reduced maintenance costs
- Greater fuel economy
- Reduced operating costs
- Smoother engine operation
- Proper engine temperatures
- Longer spark plug life
- Reduced engine vibration
EDM-730 Specifications |
|
|
|
Standard Functions of the EDM-730 |
Optional functions of the EDM-730 |
|
|
Related products
CGR-30P (2 Monitors) & CGR-30C Primary 4-Cylinder Twin Engine Monitor Combo
- Models: CGR-30P
- FAA Certifications: STC’d, PMA’d and TSO’d
- Weight: 1.1 Lbs
- Environmental: Designed and Tested to TSO (DO-160G)
- Software: Designed and Documented to TSO (DO-178B, Level C)
- Minimum Performance Standards: TSO-C43c, TSO-C44c, TSO-C45b, TSO-C47a, TSO-C48a, TSO-49b and TSO-C55a
- Power Requirements: 7.5 to 30 Volts, 0.1 amps @ 24V (Typ), 0.2 amps @ 12 Volts (Typ)
- USB Port: For USB Memory Stick use only
- Display: Active Matrix TFT, 262,144 colors, Sunlight readable
- Backlight: External control line, programmable levels
- Display of Primary Gauges with Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, One on the Secondary Screen
- Display of Primary and Non-Primary Gauges without Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, Six on the Secondary Screen
CGR-30P 6-Cylinder Primary Twin Engine Monitors, Premium (2 Monitors) w/RPM, EGT/CHT & 10 Functions
- Models: CGR-30P
- FAA Certifications: STC’d, PMA’d and TSO’d
- Weight: 1.1 Lbs
- Environmental: Designed and Tested to TSO (DO-160G)
- Software: Designed and Documented to TSO (DO-178B, Level C)
- Minimum Performance Standards: TSO-C43c, TSO-C44c, TSO-C45b, TSO-C47a, TSO-C48a, TSO-49b and TSO-C55a
- Power Requirements: 7.5 to 30 Volts, 0.1 amps @ 24V (Typ), 0.2 amps @ 12 Volts (Typ)
- USB Port: For USB Memory Stick use only
- Display: Active Matrix TFT, 262,144 colors, Sunlight readable
- Backlight: External control line, programmable levels
- Display of Primary Gauges with Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, One on the Secondary Screen
- Display of Primary and Non-Primary Gauges without Red and/or Yellow Ranges: Five on the Main Screen + EGT and CHT, Six on the Secondary Screen
Electronics International MVP-50 Glass Panel Twin Engine Monitors for 6 cylinder, TSO
MVP-50 Display
Weight:1.9 Lbs. Environmental: TSO'd to DO-160 Software: TSOd to DO-178B Power Requirements: 7.5 to 30 Volts, .3 Amps @24V (Typical), .6 Amps @ 12V (Typical). USB Port: For USB Memory Sticks Only (not intended to provide power to other electronic devices) Display: Active TFT Matrix, 262,144 colors. Sunlight readable. Backlight: External Control Line and Internal Electric EyesEDC-33P-4/6
Weight: 1 Lbs. Environmental: Meets TSO (DO-160) Software: Designed and documented to TSO (DO-178B) Power Requirements: 7.5 Volts to 30 Volts, 0.1 amps (Typical).Inputs
Volts: Measured on the power lead of the EDC. Amps: +/- 2.5V differential input, +/- 90V common mode operating range Fuel Flow: 2.5V trigger, 5.11K Ohm pull-up to +5V, 0 to 8.3KHz. RPM: 2 ea. inputs, may be configured for digital or mag input. Selectable jumper for 4 or 6 Cylinder operation. Over voltage protection for RPM: 3V trigger, impendence = 2.06K with 1V pickup. Pressure: 6 ea. inputs, 0 to 2.5V differential input. Impendence >20M Ohms, common mode = 0 to 4 Volts. Temperature: 17 ea. inputs, 0 to 2.5V differential input. Impendence = 12.1K Ohms, common mode = 0 to 4V. Resistive Fuel Level: 4 ea. inputs, 0 to 18V single ended input, impendence = 14.4K Ohms Capacitive Fuel Level: 4 ea. inputs, 0 to 6 KHz. 2.1V trigger, impendence = 33.2K OhmsEngine Data Monitor 930 System, 4 Cylinder Complete Primary Package, L/R 2 Tank, Experimental
- Dimensions: 5.97 x 5.11, 2.99 deep
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGTs
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-930 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 930 System, 4 Cylinder Complete Primary Package, L/R/Aux 4 Tank, Experimental
- Dimensions: 5.97 x 5.11, 2.99 deep
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGTs
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-930 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 960 System, 4 Cylinder Complete Primary Package, L/R 2 Tank, TSO/STC
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGT’s
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-960 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Engine Data Monitor 960 System, 6 Cylinder Complete Primary Package, Tankless, TSO/STC
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGT’s
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-960 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty
Twin Engine Data Monitor 960 System
- Pre-Wired Harness for all functions
- Display SVGA
- RPM Prop
- MAP Manifold Pressure
- % HP Percent of Horse Power
- EGT Exhaust Gas Temp.
- CHT Cylinder Head Temp.
- EGT Normalize mode
- LOP/ROP JPI Exclusive Leaning Mode
- O-T Oil Temperature
- O-P Oil Pressure
- F-P Fuel Pressure (when in POH)
- OAT Outside Air Temp.
- VDC Voltage (1)
- AMP Current amps (2 twins)
- Fuel Flow Transducer FlowScan
- GPH Gallons per Hour GPH
- REQ Required to wp or destination
- USD Fuel used
- H:M Endurance Hours and Minutes
- MPG Miles per Gal
- CLD Shock Cooling on ALL cylinders
- DIFF Difference between EGT’s
- USB Memory stick 1 GB
- Data Recording 800 Hrs every 6 sec.
- EZTrends Graphing Software free
- 3 year Warranty
- EDM-960 ALL IN ONE Bright VGA Display
- Pre-Wired Harness for all functions
- All EGT/ CHT probes
- Oil Pressure Transducer
- Oil Temperature Sensor
- Fuel Pressure Transducer
- Oat Sensor
- RPM Sensor, One required
- Manifold Pressure Transducer
- 100 amp Shunt (2)(for Amps)
- Volts pick-up V-1 and V-2
- 2 GB memory Download/upload stick
- FloScan Fuel Flow Transducer w/firesleeve
- Demo DVD
- 3 year Warranty